Embers Bristol
Tel: 0117 925 1115

Latest Case Studies

Expose chamber & leave brickwork

10-September-2016
10-September-2016 13:21
in General
by Admin


ENQUIRY

The customer wanted to remove the wooden surround and replace the existing fire with a wood burning stove.

SURVEY
We popped over to take a look at the room, chimney aperture and access to the stack. We suggested - a 5kW stove would suit the room size, a chimney sweep would be needed and the access was fine. We issued a estimate detailing the variables that may incur once the existing fireplace had been removed. Hearth and stove options were discussed.

Embers Bristol Stove Installation
Survey photo

After the estimate was accepted we booked the prep work and installation. The duration was two days with the preparation work on the first and install on the second.

PREP WORK

Once opened up we could asses the brickwork and the customer was keen to leave it bare.
We installed a front and back Italian honed slate hearth and made good to the front fascia of the breast.

INSTALLATION
The stove chosen was the 5kW Charnwood C5.
We installed a 10 meter 316 grade flxible liner.

Embers Bristol stove installation
Completed installation photo

Contact Us

0117 925 1115

Visit our showroom:
Ember Bristol,
117-119 St Georges Road,
College Green,
Bristol,
BS1 5UW

Opening Hours

Tuesday - 10.30 - 16.30
Weds - Fri - 10.30 - 17.30
[Closed for lunch - 12.30 - 13.30]
Sat - 11.00 - 16.00
[Closed for lunch - 13.00 - 14.00]
Sun - Mon - Closed

Please note we will be closed on Tues 29th October and back open from 13.30 on Weds 30th