Embers Bristol
Tel: 0117 925 1115

Latest Case Studies

No chimney in loft

10-September-2016
10-September-2016 13:20
in General
by Admin

ENQUIRY
The customer wanted a wood burning stove installed but lived in a property where the chimney stack had been removed.

SURVEY
We popped over to take a look at the room, chimney aperture and access to the stack. We suggested - a 5kW stove would suit the room size and the access was fine. We issued a estimate detailing the variables that may incur once the existing fireplace had been removed.

Embers Bristol Stove InstallationEmbers Bristol Stove Installation
Survey photos

After the estimate was accepted we booked the prep work and installation. The duration was two days with the preparation work on the first and install on the second.

PREP WORK

We removed the existing fireplace and exposed the original brick work chamber which the customer decided toi keep bare.
We installed new front and back hearths and made good to the front of the fascia.

INSTALLATION
The stove chosen was the Charnwood C5.
We installed a 316 grade flxible liner before connecting to twin wall to exit to property in the loft space.

Embers Bristol Stove InstallationEmbers Bristol
Completed installation photo

Contact Us

0117 925 1115

Visit our showroom:
Ember Bristol,
117-119 St Georges Road,
College Green,
Bristol,
BS1 5UW

Opening Hours

Tuesday - 10.30 - 16.30
Weds - Fri - 10.30 - 17.30
[Closed for lunch - 12.30 - 13.30]
Sat - 11.00 - 16.00
[Closed for lunch - 13.00 - 14.00]
Sun - Mon - Closed

Please note we will be closed on Tues 29th October and back open from 13.30 on Weds 30th